Use your own emission factors: supplier factors and EPDs

Modified on Mon, 23 Nov at 12:59 PM

Use your own emission factors: supplier factors and EPDs

Have emission factors from your suppliers, product EPDs, or factors from an earlier carbon accounting tool? You can use them in Next-gen. This article has two parts:

  1. Add your emission factors to your own emission factor library.
  2. Match them to your activity data when you upload it.

Part 1: Add your emission factors

Your own factors live under Data → Emission factors, in your emission factor library. They sit next to the factors in the Position Green library, and only your company can see them. Add them one by one, or upload many at once.

Create one factor

  1. Go to Data → Emission factors and click Create emission factor.
  2. Give it a name, a quality level and, if you like, your own ID. Leave the ID blank to get one generated, such as EF-0001.
  3. Choose the consumption unit, the emission unit and the energy unit. Need a unit such as tonne-km? Click Composite unit to combine two units.
  4. Pick a category, such as concrete or diesel fuel.
  5. Fill in the values for each life-cycle stage. Click + to add another stage.
  6. Add the source (a URL), the issued and expiry dates, and a short description of the source or method.
  7. Save.

Upload many factors

  1. Go to Data → Emission factors and click Upload.
  2. Download the template. The Excel version has a guide to every column.
  3. Fill in one row per life-cycle stage. Rows with the same ID (or the same name, if you leave the ID blank) form one factor.
  4. Upload the file, then go through the four steps: Upload, Map columns, Preview and correct, Review & import.

Uploads only add new factors. An ID or name that is already in your library is rejected. To change a factor, edit it in the library.

What a factor can include

FieldWhat to enter
Name (required)The factor's name, such as "Concrete C30/37".
Emission factor IDYour own ID, such as the EPD number. Leave blank to get one generated. You use this ID in Part 2.
CategoryWhat the factor is, such as "concrete" or "diesel fuel". Leave blank to match it from the name.
Life-cycle stageThe stage the values cover. One row per stage. Blank means cradle to gate.
Emission factorTotal CO₂e per consumption unit.
Market-based factorFor electricity: the market-based value, such as the residual mix or your supplier's contract factor.
Consumption unitWhat the values are per: the EPD's declared unit, such as kg, tonne, m³, kWh, L, km or item.
Emission unitkg, g or tonne. Blank means kg.
CO₂, CH₄, N₂OOptional split of the fossil total, in CO₂e. The three must add up to the total.
Biogenic CO₂Reported separately. It is not part of the CO₂e total.
Energy and energy unitEnergy use per consumption unit, such as MJ or kWh.
GHG categoryWhere this stage counts. Leave blank to place it automatically from the category and stage.
Region and yearWhere and when the factor applies, such as NOR and 2025. Blank year means the current year.
Issued and expiry dateFor EPDs. An expiry date in the past is imported with a warning.
Source and descriptionA URL or citation, and free text about the factor or method.
QualitySpecific, Average or Spend. Blank means Average. Use Specific for product EPDs and supplier factors.
Emission groupThe group that activity priced with this factor goes into, when the activity file names no group itself.

Life-cycle stages we support

  • EN 15804 modules: A1, A1–A3, A2, A3, A4, A5, B1 to B7, C1 to C4.
  • Common scopes: cradle to gate, cradle to grave, gate to gate, gate to grave, use phase, end of life.
  • Fuels and energy: well to tank, tank to wheel, well to wheel, transmission and distribution, well to tank plus transmission and distribution.

Module D (benefits beyond the system boundary) is not supported. Each stage can count in its own GHG category, so an EPD's A4 transport can land somewhere else than its A1–A3 production.

Example: an EPD with three stages

nameemission_factor_idlca_stageemission_factorconsumption_unitquality
Concrete C30/37NEPD-1234-567-ENA1_A30.115kgSpecific
Concrete C30/37NEPD-1234-567-ENA40.006kgSpecific
Concrete C30/37NEPD-1234-567-ENC30.002kgSpecific

The three rows share one ID, so they become one factor with three stages.

Part 2: Match your factors to your activity data

Once your factors are in the library, point your activity data to them. Next-gen then uses your factor directly, without looking for a match in the Position Green library.

  1. Prepare your activity file. Use the Structured activity data template, or your own file. Each row needs a description, the consumption, the consumption unit and a date.
  2. Add a column with the ID of the factor to use on each row.
  3. Go to Data → Uploads → Upload new file and choose Structured activity data.
  4. Upload the file. When you map columns, map your ID column to Emission factor ID.
  5. Validate, review and confirm.

Rows with a valid ID use your factor. Rows without an ID are still matched against your own factors first, then against the library. See Upload activity data and pre-calculated emissions for the rest of the upload.

Make sure the match works

  • Units must fit. If your factor is per kg and the row is in liters, Next-gen can't use your factor. The row goes to normal matching instead, and may end up spend-based.
  • IDs must be exact. If Next-gen can't find the ID, the row goes to normal matching too.
  • Set the GHG category if you need to. A GHG category in the activity file is used for the main part of the factor. Stages such as fuel production keep their own category.
  • Keep a clear description. A product code alone is hard to review later. Add a short description next to it.
  • Check after upload. Open a few rows and check that they used your factor.

Pick your own factors by hand

Your factors also show up in the factor picker, so you can choose them for any line, like any other factor. See Change an emission factor.

Good to know

  • We don't update your factors. Position Green updates library factors every year, but factors you add stay as they are. Keep them current, and watch expiry dates on EPDs. See Emission Factor Library.
  • See where a factor is used. The library shows how many consumptions use each of your factors.
  • Already have the emissions, not the factor? You can upload pre-calculated emissions instead. Activity plus a factor is better where you can: it gives a stronger audit trail and better input for reduction planning.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article